Note
Action
xx2000001683
Pull the cable package out to the swing support.
4
Removing the swing support
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx2000001684
Remove the swing support.
Tip
If the lower arm support is hard to loosen from
the swing, use a plastic hammer to knock on the
lower arm support lightly.
3
Supporting the lower and upper arms with roundslings
Note
The lower and upper arms include the lower arm, housing, extender unit (only
for IRB 1300-7/1.4 and IRB 1300-12/1.4), tubular and tilt unit.
Continues on next page
604
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 gearbox
Continued