Note
Action
Ring of the axis-2 sealing assembly
tool, included in Special toolkit for
IP67/Clean Room/Foundry Plus
robots (3HAC078203-001).
xx2000002463
For robots with protection type Foundry Plus
(option 3352-10)
Place the ring of the axis-2 sealing assembly tool
against the sealing.
xx2000002562
6
Small circular plate of the axis-2
sealing assembly tool, included in
Special toolkit for IP67/Clean
Room/Foundry Plus robots
(3HAC078203-001).
xx2000002464
Fit the small circular plate of the axis-2 sealing
assembly tool and fix with three M6x75 screws.
7
xx2000002465
Screw the screws, little by little and evenly, to
press the sealing into place.
8
Remove the assembly tool.
9
Check that the sealing is undamaged and properly
fitted.
10
Continues on next page
Product manual - IRB 1300
613
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 gearbox