Note
Action
xx2000001678
Make sure that :
•
the block on the mechanical stop flange is
towards the upper side (process hub side).
•
the notches on the extender unit/tubular
and the mechanical stop flange are aligned.
3
Valid for IRB 1300-11/0.9 and IRB
1300-10/1.15
xx2000001718
Valid for IRB 1300-7/1.4 and IRB
1300-12/1.4
xx2000001677
Check the radial sealing on the housing (IP67, Clean Room and Foundry Plus)
Note
Action
For robots with protection type Clean Room:
1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
xx2000002483
Check the radial sealing on the housing.
Replace if damaged, as described below.
2
Continues on next page
696
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 gearbox
Continued