3.6.2 Customer connections
Introduction to customer connections
The cables for customer connection are integrated in the robot and the connectors
are placed on the tubular and one at the base. There are two connectors R2.C1
and R2.C3 at the tubular. Corresponding connectors R1.C1 and R1.C3 are located
at the base.
There is also connections for Ethernet, one connector R2.C2 at the tubular and
the corresponding connector R1.C2 located at the base.
Hose for compressed air is also integrated into the manipulator. There are 4 inlets
at the base (R1/8”) and 4 outlets (M5) on the tubular.
(A)
(A)
(A)
(B)
(B)
(B)
(C)
(C)
(D)
(D)
xx2000001007
Value
Number
Description
Connection
Position
30 V, 1.5 A
12 wires
Customer power/signal
(R1)R2.C1
A
30 V, 1 A or 1 Gbits/s
8 wires
Customer power/signal
or Ethernet
(R1)R2.C2
B
42 V DC or 25 V AC, 4 A
i
4 wires
Customer power/signal
(R1)R2.C3
C
Outer diameter of air hose:
6 mm
4
Max. 6 bar
Air
D
i
Contact ABB for more information if to use the (R1)R2.C3 connection for an application with a
higher voltage.
Continues on next page
94
Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.6.2 Customer connections
Summary of Contents for IRB 1300
Page 1: ...ROBOTICS Product manual IRB 1300 ...
Page 8: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 100: ...This page is intentionally left blank ...
Page 746: ...This page is intentionally left blank ...
Page 762: ...This page is intentionally left blank ...
Page 764: ...This page is intentionally left blank ...
Page 768: ......
Page 769: ......