3.2.2 Maintenance schedule
General
The robot must be maintained regularly to ensure proper function. The maintenance
activities and intervals are specified in the table below.
Unexpected situations that arise prompt inspection of the robot. Any damage must
be attended to immediately!
The inspection intervals
do not
specify the life of each component.
Maintenance schedule
The table below specifies the required maintenance activities and intervals:
Detailed in section
Interval
Equipment
Maintenance
activity
40,000 hrs
Gearbox oil, axes 1 to 4
Maintenance
free
IRB 1600
Replace any damaged,
missing or unreadable
labels.
12 months
Information labels
Inspection
Inspecting information
labels on page 135
Changing the oil in axes
5 and 6 gearboxes on
page 138
.
20,000 hrs
Gearbox oil, axes 5 and 6
IRB 1600
Changing
Changing the oil in axes
5 and axis 5 and 6 gear-
boxes, IRB
1600ID/1660ID on
page 141
20,000 hrs
Gearbox oil, axes 5-6
IRB 1600ID-4/1.5
Changing
Changing the oil in axes
5 and axis 5 and 6 gear-
boxes, IRB
1600ID/1660ID on
page 141
20,000 hrs
Gearbox oil, axes 5-6
IRB 1660ID-X/1.55
Changing
Replacing the battery
pack on page 144
36 months or bat-
tery low alert
i
Battery pack, measurement
system of type RMU101 or
RMU102 (3-pole battery
contact)
Replacement
Replacing the battery
pack on page 144
.
Battery low alert
ii
Battery pack, measurement
system with 2-pole battery
contact, e.g. DSQC633A
Replacement
Cleaning the IRB
1600/1660ID on page149
Regular
iii
Complete robot
Cleaning
i
The battery low alert (38213
Battery charge low
) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
ii
The battery low alert (38213
Battery charge low
) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
Continues on next page
Product manual - IRB 1600/1660
129
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
3 Maintenance
3.2.2 Maintenance schedule
Summary of Contents for IRB 1600
Page 1: ...ROBOTICS Product manual IRB 1600 1660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 336: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 396: ......
Page 397: ......