Draining, axis 5-6 gearbox
Use this procedure to drain the axis 5-6 gearbox.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
WARNING
Handling gearbox oil involves several
safety risks. Before proceeding, please
observe the safety information in sec-
tion
gearbox lubricants (oil or grease) on
page 38
2
The capacity of the vessel must be sufficient
to take the complete amount of oil.
xx0700000033
Position the robot as shown in the fig-
ure to the right:
•
upper arm: upwards for a stand-
ing robot.
•
axis 4: - 90º, to a position where
the oil plug (A) is faced down-
wards.
Note
The total amount of oil will not be
drained. There will remain approxim-
ately 20 ml in the wrist unit.
3
CAUTION
The gearbox can contain an
excess of
pressure
that can be hazardous. Open
the oil plug carefully in order to let out
the excess pressure.
4
Shown in figure
Location of oil plugs, axis 5-6
.
Remove the oil plug (A) and the ventil-
ation plug (B).
5
Continues on next page
142
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
3 Maintenance
3.4.3 Changing the oil in axes 5 and axis 5 and 6 gearboxes, IRB 1600ID/1660ID
Continued
Summary of Contents for IRB 1600
Page 1: ...ROBOTICS Product manual IRB 1600 1660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 336: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 396: ......
Page 397: ......