Removing the damper
Use this procedure to remove the damper.
Note
Action
CAUTION
Always cut the paint with a knife and grind
the paint edge when disassembling parts.
See
Cut the paint or surface on the robot be-
fore replacing parts on page 159
1
Run the robot to a position where it is best
to enable access to the attachment screw of
the damper.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot work-
ing area.
3
Remove the damper by unscrewing the attach-
ment screw and washer.
4
Refitting the damper
Use this procedure to refit the damper.
Note
Action
Run the robot to a position where it is best
to enable access to the attachment screw of
the damper.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot work-
ing area.
2
1 pc: M6 x 16.
Secure the damper with the attachment screw
and washer.
3
DANGER
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section
may cause injury or damage on page 28
4
Product manual - IRB 1600/1660
221
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.4.7 Replacing the damper, axis 2
Continued
Summary of Contents for IRB 1600
Page 1: ...ROBOTICS Product manual IRB 1600 1660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 336: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 396: ......
Page 397: ......