2.3.8 Installation of signal lamp for 1600 (option)
General
A signal lamp with an yellow fixed light can be mounted on the robot, as a safety
device. The signal lamp is required on an UL/UR approved robot.
The lamp is active in MOTORS ON mode.
Note
Do not use the signal lamp option in a Clean Room environment.
Different signal lamps on IRB 1600 and IRB 1600ID
This instruction details how to install the signal lamp on IRB 1600. If installing the
lamp on an IRB 1600ID or an IRB 1660ID robot, see
Installation of signal lamp for
1600ID/1660ID (option) on page 95
.
Location of signal lamp
The signal lamp is fitted to the upper arm housing of the robot, as shown in the
figure below.
xx0400001265
Signal lamp
A
Cable gland
C
Continues on next page
92
Product manual - IRB 1600/1660
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
2 Installation and commissioning
2.3.8 Installation of signal lamp for 1600 (option)