4 Repair
4.2.3. Mounting instructions for seals
3HAC022031-001 Revision: C
80
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Flange seals and static seals
The procedure below details how to fit flange seals and static seals.
O-rings
The procedure below details how to fit o-rings.
Action
1. Check the flange surfaces. They must be even and free from pores.
It is easy to check flatness using a gauge on the fastened joint (without sealing
compound).
If the flange surfaces are defective, the parts may not be used because leakage could
occur.
2. Clean the surfaces properly and in accordance with ABB recommendations.
3. Distribute the sealing compound evenly over the surface, preferably with a brush.
4. Tighten the screws evenly when fastening the flange joint.
Action
Note
1. Ensure that the correct o-ring size is used.
2. Check the o-ring for surface defects, burrs,
shape accuracy, etc.
Defective o-rings may not be used.
3. Check the o-ring grooves.
The grooves must be geometrically correct and
free from pores and contamination.
Defective o-rings may not be used.
4. Lubricate the o-ring with grease.
5. Tighten the screws evenly when assembling.
Continued
Summary of Contents for IRB 2400/L
Page 1: ...Product manual Articulated robot IRB 2400 L IRB 2400 10 IRB 2400 16 M2000 M2000A M2004 ...
Page 2: ......
Page 8: ...Table of Contents 6 3HAC022031 001 Revision C Copyright 2004 2008 ABB All rights reserved ...
Page 191: ......
Page 192: ......
Page 193: ......
Page 194: ......
Page 195: ......
Page 198: ......
Page 199: ......
Page 202: ......
Page 203: ......
Page 205: ......
Page 226: ......