1.4 Calibration and references
1.4.1 Calibration methods
Overview
This section specifies the different types of calibration and the calibration methods
that are supplied by ABB.
The original calibration data delivered with the robot is generated when the robot
is floor mounted. If the robot is not floor mounted, then the robot accuracy could
be affected. The robot needs to be calibrated after it is mounted.
More information is available in the product manual.
Types of calibration
Calibration method
Description
Type of calibration
Axis Calibration or Cal-
ibration Pendulum
i
The calibrated robot is positioned at calibration
position.
Standard calibration data is found on the SMB
(serial measurement board) or EIB in the robot.
Standard calibration
For robots with RobotWare 5.04 or older, the
calibration data is delivered in a file, calib.cfg,
supplied with the robot at delivery. The file
identifies the correct resolver/motor position
corresponding to the robot home position.
CalibWare
Based on standard calibration, and besides
positioning the robot at synchronization posi-
tion, the Absolute accuracy calibration also
compensates for:
•
Mechanical tolerances in the robot
structure
•
Deflection due to load
Absolute accuracy calibration focuses on pos-
itioning accuracy in the Cartesian coordinate
system for the robot.
Absolute accuracy
calibration (option-
al)
Absolute accuracy calibration data is found
on the SMB (serial measurement board) in the
robot.
For robots with RobotWare 5.05 or older, the
absolute accuracy calibration data is delivered
in a file, absacc.cfg, supplied with the robot at
delivery. The file replaces the calib.cfg file and
identifies motor positions as well as absolute
accuracy compensation parameters.
A robot calibrated with Absolute accuracy has
a sticker next to the identification plate of the
robot.
To regain 100% Absolute accuracy perform-
ance, the robot must be recalibrated for abso-
lute accuracy after repair or maintenance that
affects the mechanical structure.
xx0400001197
Continues on next page
30
Product specification - IRB 2600
3HAC035959-001 Revision: AA
© Copyright 2009-2021 ABB. All rights reserved.
1 Description
1.4.1 Calibration methods
Summary of Contents for IRB 2600
Page 1: ...ROBOTICS Product specification IRB 2600 ...
Page 6: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 96: ......
Page 97: ......