Extra equipment connections
Connections to the:
•
air hose ( 3/8") is located on the front part of the upper arm and at the base.
Max. 8 bar. Inner diameter of the air hose: 9.5 mm.
Number of signals, customer connections option Parallel&Air (803-1):
•
23 (50V, 0.5A)
•
9 (300V, 2A). 8 are double crimped in R1.CP/CS and 1 is only accessible in
the robot base.
•
1 protective ground
Number of signals, customer connections option Ethernet, Parallel&Air (803-2)
and DeviceNet, Parallel&Air (803-3):
•
8 (50V, 0.5A)
•
3 (300V, 2A)
•
2 DeviceNet
•
4 EtherNet
•
1 protective ground
Number of signals, customer connections option Profibus, Parallel&Air (803-4):
•
8 (50V, 0.5A)
•
2 (300V, 2A)
•
2 Profibus
•
1 protective ground
Connection sets
To connect power and signal conductors to the robot base/upper arm connectors,
the following parts are recommended.
Content
Art. no.
Connector
Connection
set
•
Sockets for cable area of 0.14-2.5
mm²
•
Hood foundry
•
Hinged frame, hood
•
Multicontact-module, female
3HAC16667-1
R1.CP/CS
PROC1 on
base
•
Hose coupling
•
M12 connector, male
3HAC033181-001
R1.ETHER-
NET
Connector set
on base
•
Pins for cable area 0.21 - 0.93
mm
2
•
Bottle shaped shrinking hose
•
Angle shaped shrinking hose
•
Hose coupling
3HAC025396-001
R2.CP/R2.CS
R2.CP/R2.CS
•
Pins for cable area 0.21 - 0.93
mm
2
•
Bottle shaped shrinking hose
•
Angle shaped shrinking hose
3HAC070439-001
R2.ETHER-
NET
Connector set
upper arm
Continues on next page
72
Product specification - IRB 2600
3HAC035959-001 Revision: AA
© Copyright 2009-2021 ABB. All rights reserved.
1 Description
1.10.1 Customer connection on robot
Continued
Summary of Contents for IRB 2600
Page 1: ...ROBOTICS Product specification IRB 2600 ...
Page 6: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 92: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 96: ......
Page 97: ......