Note
Action
xx0900000014
Disconnect the following connectors on the
base cover
:
•
R1.CP/CS
•
R1.MP
•
R1.ETHERNET (if used)
Tip
Do not remove the
R1.SMB-connector
and
air hose connector
at this stage. It will be
easier to remove these two when the cover
base has been removed.
3
Parts:
•
A: R1.CP/CS
•
B: R1.MP
•
C: Air hose connector
•
D: Position of R1.ETHERNET (if
used)
•
E: R1.SMB
A
B
C
xx0800000456
A Base
B Cover base
C Attachment screws
Remove the
cover base
.
4
Disconnect connectors on the brake release
unit:
•
X8
•
X9
•
X10
5
Continues on next page
204
Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness