Note
Action
xx0900000099
Cut the
cable straps
securing the battery
cable.
6
Parts:
•
A: Cable straps (2 pcs)
Disconnect the battery cable.
7
A
B
C
D
xx1200000889
A Thin nut, width 30 mm
B R1.SMB
C Bracket
D Air connector
Unscrew the thin nut securing the R1.SMB
connector on the outside of the bracket.
Tip
Use a deep well hexagon socket, width 30
mm (like the ones used for spark plugs, or
similar).
xx1200000888
8
Unscrew the nut for the air connection on
the inside of the bracket.
9
Continues on next page