3 Maintenance
3.5.1. Gearboxes, axes 1- 4
3HAC030005-001 Revision: -
100
©
Copyri
ght 200
6 ABB
.
All ri
ghts res
erved.
Interval 30,000 hrs or 5 Years
Oil change in axis 1-3
3. Remove the oil plug,
and drain the oil from
gearbox 4.
xx0700000728
4. Fill new oil through the
plug holes, with
specified volume.
Specified volume see
Oil and Grease specification on page
5. Refit the oil plugs,
apply Loctite 243.
NOTE!
If the sealing ring on the
Sealing Plug is
damage, change the
Sealing Plug.
Tightening Torque 4 Nm.
6. Refit the (12 pcs) M6
screws holding the
base cover.
(If necessary, change
the sealings)
Replacement of base cover gasket on
.
Action
Note
Action
Note
1. Remove the (12 pcs)
M6 screws holding the
base cover.
Replacement of base cover gasket on
.
2. Remove the parallel
arms.
Replacement of Parallel Arms on page
3. Remove the Telescopic
Shaft
Described in section
Replacement of Telescopic Shaft on page
Continued
Continues on next page