3 Maintenance
3.4.1. Changing the Battery in the Measuring System
3HAC030005-001 Revision: -
96
©
Copyri
ght 200
6 ABB
.
All ri
ghts res
erved.
Required Equipment and References
Changing the Battery
DANGER!
Turn off all electric power, hydraulic and pneumatic pressure supplies to the robot.
Tools and wear parts
Spare part no.
Note
Battery Pack
Spare Parts, SMB Unit on
page 213
Lithium battery
Standard tools
Battery retainer (strap)
References
Updating revolution counters on page 182
Replacement of base cover gasket on page 116
Action
Note
1. Remove the (12pcs) M6
screws holding the base
cover.
Described in section
Replacement of base cover gasket on
.
2. Remove the base
cover.
3. Disconnect the battery
from the serial
measurement board.
Connection (X3).
NOTE!
Voltage of batteries,
measured at power off:
Min. 7 Volt. Max. 12 Volt
xx0700000504
A. Battery retainer (strap)
B. Battery
C. Battery connection
D. Serial Measurement Board
4. Cut the strap and
remove the battery
pack.
Use standard tools.
A
B
C
D
Continued
Continues on next page