2 Installation and Commissioning
2.5.3. Installation of Vacuum System (Optional)
3HAC030005-001 Revision: -
64
©
Copyri
ght 200
6 ABB
.
All ri
ghts res
erved.
2.5.3. Installation of Vacuum System (Optional)
General
This section describes installation of (Optional) vacuum system on a IRB 360.
DANGER!
Turn off all electrical power, hydraulic and pneumatic pressure supplies to the robot!
Also read the safety sections:
•
Safety risks related to pneumatic/hydraulic systems on page 18
•
Risks associated with live electric parts on page 20
•
Safety risks during installation and service work on robot on page 15
Locations
xx0700000654
A
Ejector unit
B
R1.CS
C
Exhaust air
D
Vacuum In
E
Compressed air in (max. 6 bar)
F
Vacuum switch
G
Air filter (compressed air side)
H
Air filter (vacuum side)