Illustration
xx0700000704
Hexagon bolt with flange M6x20 (A2 DIN6921)
A
Nuts for the air nozzles
B
Ejector unit
C
Front plate
D
Gasket
E
Pressure guard nut
F
Pressure guard cap
G
Removal
Note
Action
Disconnect the air supply, vacuum hoses, and signal
cable from the ejector unit.
1
Described in section
of base cover gasket on page 167
Remove the base cover.
2
Use standard tools.
Remove the 2x hexagon socket head cap screw
M8x35 holding the filter holder, and remove the fil-
ters.
3
Remove all the nuts for the air nozzles, pressure
guard cap and the pressure guard nut.
4
Remove the ejector unit inwards direction.
5
Continues on next page
Product manual - IRB 360
227
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacement of ejector unit
Continued