Calibrating axis 4
Note
Action
In manual mode, tap
Jogging
in the ABB
menu.
1
Tap
Motion mode
to choose group of
axes to jog.
2
Tap
Axis 4-6
to jog axis 4.
3
See figure in
Jog axis 4 so that the calibration marks
are in line.
4
Described in section
ure on FlexPendant on page 247
Store the resolver value by doing a fine
calibration.
5
Described in section
Check the position.
6
246
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
5 Calibration information
5.6 Calibrating axis 4
Continued