3.2.2 Regular maintenance
Recommendation
The robot is designed to be able to work under very demanding conditions with a
minimum of maintenance. Time between services can vary depending on the
influence of the environment the robot is exposed for. We strongly recommend
that at every stop in production, especially after collisions and after every wash
down, the robot is inspected concerning the following parts.
Inspect regularly
•
Telescopic shaft
•
Spring units
•
Bars
•
Universal joints
Preventive maintenance
Nevertheless, certain routine checks and preventive maintenance must be carried
out at specified periodic intervals, as shown in the following table.
Note
Preventive maintenance
As described in section
.
Clean the robot.
Recommended lubrication, see
section:
•
Mounting instructions for
bearings on page 158
Lubricate sealings:
•
At regular intervals
•
When needed.
Controller:
•
Check that the sealing joints and cable glands are
really airtight so that dust and dirt are not sucked
into the cabinet.
Product manual - IRB 360
99
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
3 Maintenance
3.2.2 Regular maintenance
Summary of Contents for IRB 360 Series
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 156: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 258: ...This page is intentionally left blank ...
Page 276: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 283: ......