3.2.3 Maintenance schedule IRB 360
Maintenance schedule
30,000h
5 year
4,000h
2 year
500h
400h
Daily
Equipment
Maintenance
activity
x
i
Clean Room robot
Inspection
x
Telescopic shaft
Inspection
x
x
ii
Vacuum system
Inspection
x
x
Bar system
Inspection
x
Upper arms
Inspection
x
iii
Spring unit
Inspection
x
Movable plate
Inspection
x
Sealing ring (V-ring)
Inspection
Information labels
Inspection
x
iv
Telescopic shaft (WDS)
Grease
x
Bearing rings 3HAC2091-1
v
Grease
x
Telescopic shaft including
universal joints
Changing
x
vi
Gearboxes oil, axes 1, 2, and
3
Changing
x
Gearbox oil, axis 4
Changing
36 months
or battery
low alert
vii
Battery pack, measurement
system of type RMU101 or
RMU102 (3-pole battery con-
tact)
Replacement
24 months
or battery
low alert
viii
Battery pack, measurement
system with 2-pole battery
contact, e.g. DSQC633A
Replacement
i
Check for abnormal wear or contamination.
ii
Only if option is chosen. Change interval is dependant on the material in picked objects. Porous
objects may cause shorter cleaning intervals.
iii
Grease if the spring units make a grinding sound.
iv Check for abnormal wear or contamination
v
There are two different types of bearing rings, 3HAC028087-001 is maintenance-free, 3HAC2091-1
must be lubricated according to maintenance schedule. See
Different versions of bearing rings
require different maintenance procedures on page 112
vi Oil should only be changed once after the first 30,000 h.
vii The battery low alert (38213
Battery charge low
) is displayed when the battery needs to be replaced.
The recommendation to avoid an unsynchronized robot is to keep the power to the controller turned
on until the battery is to be replaced.
See the replacement instruction for more details.
viii The battery low alert (38213
Battery charge low
) is displayed when remaining backup capacity
(robot powered off) is less than 2 months. The typical lifetime of a new battery is 36 months if the
robot is powered off 2 days/week or 18 months if the robot is powered off 16 h/day. The lifetime
can be extended with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
Continues on next page
100
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
3 Maintenance
3.2.3 Maintenance schedule IRB 360
Summary of Contents for IRB 360 Series
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 156: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 258: ...This page is intentionally left blank ...
Page 276: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 283: ......