3.3.6 Joint balls
General
This section describes maintenance on the joint balls, with the interval 4000 hours.
DANGER
Turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
Also read the safety sections:
•
Safety risks related to pneumatic/hydraulic systems on page 33
•
Risks associated with live electric parts on page 29
•
Safety risks during installation and service work on robots on page 23
Check joint balls
xx0700000500
Movable plate
A
Joint balls
B
Required equipment and references
Note
Spare part No.
Required equipment
Standard tools
3HAC6194-1
Pliers for parallel arms
References
Replacement of joint balls on page 195
Interval 4,000 hours or 2 years
Note
Action
If necessary replace the part as de-
scribed in
Check surface of joint balls for cracks or burrs.
1
Product manual - IRB 360
115
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
3 Maintenance
3.3.6 Joint balls