3.6.3 Wash down cleaning
Required equipment
Note
Equipment
High pressure washer
Cloth
Usable detergents
Old designation
Type
Detergent
P3-Topax 12
Topaz LD1
Detergent
P3-Topax 99
P3-Topax 990
Disinfectant
Cleaning instructions
DANGER
turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
Also read the safety sections:
•
Safety risks related to pneumatic/hydraulic systems on page 33
•
Risks associated with live electric parts on page 29
•
Safety risks during installation and service work on robots on page 23
Note
Action
•
Water temperature: max. 80°C
Pre-rinse with water for removal
of rough soil.
1
See figure for
•
Detergent: Topaz LD1,
•
Concentration: 3 %
•
Water temperature: 40 - 60°C
Foam the whole external surface
with detergent.
2
Let the detergent work for ap-
prox 20 minutes to retain effect-
ive cleaning properties.
3
Ensure that the solvent does not
dry on the surface.
Rinse thoroughly with water.
4
•
Detergent: P3-topactive DES
•
Concentration: 1 - 2%.
•
Water temperature: 10 - 40°C
•
Time approx. 20 min.
Apply the disinfectant. Time,
concentration, and water temper-
ature are chosen to reach the
desired effect.
5
Rinse thoroughly with water.
6
After cleaning bearing races,
swivel cup sealing and sealing
ring (V-ring), lubricate them with
provision classified grease.
7
Continues on next page
148
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
3 Maintenance
3.6.3 Wash down cleaning
Summary of Contents for IRB 360 Series
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 46: ...This page is intentionally left blank ...
Page 156: ...This page is intentionally left blank ...
Page 236: ...This page is intentionally left blank ...
Page 258: ...This page is intentionally left blank ...
Page 276: ...This page is intentionally left blank ...
Page 278: ...This page is intentionally left blank ...
Page 283: ......