4.3.6 Replacement of movable plate
General
This section describes how to replace the movable plate.
DANGER
Turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
Also read the safety sections:
•
Safety risks related to pneumatic/hydraulic systems on page 33
•
Risks associated with live electric parts on page 29
•
Safety risks during installation and service work on robots on page 23
Location
IRB 360 - 1/1130, IRB 360 - 3/1130, IRB 360 - 1/800, IRB 360 - 1/1600
A
B
C
xx0700000532
Universal joint
A
Set screw, dog point
B
Sealing ring (V-ring)
C
Continues on next page
186
Product manual - IRB 360
3HAC030005-001 Revision: U
© Copyright 2008-2018 ABB. All rights reserved.
4 Repair
4.3.6 Replacement of movable plate