References
Replacement of base cover gasket on page 160
Replacement of parallel arms on page 167
Replacement of telescopic shaft on page 182
Replacement of upper arm on page 172
Interval 30,000 hours or 5 years
Oil change in axis 4, (not in 3D version)
Note
Oil should only be changed once after the first 30,000 h.
Note
Action
Described in section
Replacement of base cover gasket on
.
Remove the base cover.
1
Described in section
Replacement of gearbox unit 4 on
.
Remove the gearbox
and motor axis 4.
2
xx0700000728
Remove the oil plug,
and drain the oil from
gearbox 4.
3
Types and volumes of oil are specified in the
Technical refer-
ence manual - Lubrication in gearboxes
-
3HAC042927-001
.
Fill new oil through the
plug holes, with spe-
cified volume.
4
Continues on next page
Product manual - IRB 360
129
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
3 Maintenance
3.5.2 Gearboxes, axes 1- 4
Continued