Note
Action
xx1700000047
Decrease force to 0N.
4
xx1700000048
Apply torque 0,2 Nm, i.e. 2N on a distance of
100 mm from center of rotation.
5
Register first measurement point.
6
xx1700000049
Apply torque 1 Nm in the other direction, i.e.
10 N on a distance of 100 mm from center of
rotation.
7
Decrease force to 0N.
8
Continues on next page
Product manual - IRB 360
147
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
3 Maintenance
3.7.1 Measuring backlash axis 4
Continued