Note
Spare part no.
Equipment
See
Product manual,
spare parts - IRB 360
.
Serial measurement unit
(If damaged)
See
Product manual,
spare parts - IRB 360
.
Base cover gasket
(If damaged)
See
Product manual,
spare parts - IRB 360
.
Plastic washer
References
Circuit diagram - IRB 360
Updating revolution counters on page 241
Replacement of base cover gasket on page 160
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page 158
.
Removal SMB unit
Note
Action
Described in section
of base cover gasket on page 160
Remove the base cover.
1
Use standard tools
Remove the three(3) flange screws holding the
bracket for the SMB unit.
2
Disconnect all the cables from the SMB unit.
3
Remove the SMB unit.
4
Note
This product contains certain materials considered hazardous. This product
must
be disposed of in accordance with the current legislation of the country in which
the robot and control unit is installed.
Refitting SMB unit
Note
Check the new battery, using a voltameter. It should read 12V.
Note
Action
Refit the new SMB unit.
1
As described in circuit diagram
3HAC028647-009
Connect all cables.
2
Tightening torque 4 Nm
Refit the bracket using the three(3) flange screws.
3
Described in section
of base cover gasket on page 160
Refit the base cover.
4
Continues on next page
Product manual - IRB 360
165
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
4 Repair
4.3.2 Replacement of serial measurement board
Continued
Summary of Contents for IRB 360
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 266: ...This page is intentionally left blank ...
Page 268: ...This page is intentionally left blank ...