Note
Action
xx0700000601
Remove the two
flangescrews (B) holding
the flange (C). If neces-
sary, change the sealing
ring (A) and the flange
gasket (D).
Note
Do not use the sealing
ring (A) on robots with
protection Clean Room or
Stainless Clean Room.
6
Refitting
Note
Action
Tightening torque 4 Nm.
Refit the flange with the new mounted sealing ring,
using the two screws with Loctite 243 and the new
flange gasket.
Tip
Mounting instructions for sealings on page 152
1
Tightening torque 11 Nm.
Refit the upper arm using the 6x hex socket head
cap screw M6 x 40 (12.9 Gleitmo) and 6x plain
washer 6.4x12x1.6 steel A2-F.
2
By hand.
Fit a new VK-cover.
3
Described in section
Refit the parallel arm.
4
See
.
Recalibrate the robot.
5
174
Product manual - IRB 360
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
4 Repair
4.3.4 Replacement of upper arm
Continued