Removal
CAUTION
The spring units must be removed according to the description in section
Replacement of parallel arms on page 167
or they will be damaged.
Note
Action
Described in section
Remove all air / vacuum hoses from the
swivel cup on the movable plate.
1
Described in section
Remove all three parallel arms from the
movable plate.
2
Use standard tools.
Hold the movable plate while raising the
sealing ring (C) and removing the set
screw (B) that locks the universal joint.
Remove the movable plate from the tele-
scopic shaft.
3
Calibration mark, axis 4
IRB 360 - 1/1130, IRB 360 - 3/1130, IRB 360 - 1/800, IRB 360 - 1/1600
xx0700000629
Axis 4 calibration mark
A
IRB 360 - 8/1130, IRB 360 - 6/1600