Note
Spare part no.
Equipment
Loctite 7649
Activator
References
Replacement of parallel arms on page 167
Replacement of movable plate on page 178
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page 158
.
Removal
xx0700000500
Movable plate
A
Joint ball movable plate
B
CAUTION
Never use unnecessary force when removing the springs. Only work on one side
or the spring will be overstressed.
Note
Action
Described in section
Remove the parallel arms.
1
Described in section
Remove the movable plate.
2
Use standard tools.
Remove the joint balls.
Note
Locking liquid secures the joint balls to the movable
plate. A heat gun must be used if the movable plate
is stainless, for other materials it is optional. Do not
aim the heat on plastic parts.
3
Continues on next page
188
Product manual - IRB 360
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
4 Repair
4.3.9 Replacement of joint balls
Continued