Mounting equipment to flange on movable plate with swivel
IRB 360 - 1/1130, IRB 360 - 3/1130, IRB 360 - 1/800, IRB 360 - 1/1600
xx0700000523
4 pcs Screws M4
A
Note
Action
Attach the tool to the mounting flange.
1
CAUTION
Always use an open-end spanner 22 mm or similar
on the mounting flange, when tightening.
2
Attachment screws
Note
Attachments
M4 (Length depending on tool)
Suitable screws, lightly lubricated:
Suitable washer.
See section
Tightening torque.
Product manual - IRB 360
71
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
2 Installation and commissioning
2.4.7 Fitting equipment on robot
Continued