Note
Connection point B
Connection point A
Spec.
Wire
Type
Term
Desig-
nation
Type
Term
Desig-
nation
15
23
R1.CS
4
D10
XP5
12 BK
12.1
Conductor to cut off.
12 OG
12.2
Conductor to cut off.
13 BK
13.1
Conductor to cut off.
13 GN
13.2
Conductor to cut off.
14.1
Conductor to cut off.
14.2
Conductor to cut off.
15.1
Conductor to cut off.
15.2
Conductor to cut off.
16.1
Conductor to cut off.
16.2
0V (Ground)
20
Earth
Ref.
(DP
shield)
XP5
Shield
i
Use green/yellow shrinking hose on free conductors, in both ends.
ii
Dual press both shields, and connect them to earth.
Installation
Note
Action
Remove the standard cover plate.
1
Fit the self-adhesive gasket on the customer cover
plate.
2
Use standard tools.
Install the customer cable harness.
3
Tightening torque 4 Nm
Assemble the customer cover plate using the four
attachment screws.
4
80
Product manual - IRB 360
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
2 Installation and commissioning