3.4 Replacement/changing activities
3.4.1 Changing the battery in the measuring system
Note
The battery low alert (38213
Battery charge low
) is displayed when the battery
needs to be replaced. The recommendation to avoid an unsynchronized robot
is to keep the power to the controller turned on until the battery is to be replaced.
For an SMB board with 3-pole battery contact (RMU101 3HAC044168-001 or
RMU102 3HAC043904-001), the lifetime of a new battery is typically 36 months.
For an SMB board with 2-pole battery contact, the typical lifetime of a new battery
is 36 months if the robot is powered off 2 days/week or 18 months if the robot is
powered off 16 h/day. The lifetime can be extended for longer production breaks
with a battery shutdown service routine. See
Operating manual - IRC5 with
FlexPendant
for instructions.
DANGER
Turn off all electrical power, hydraulic and pneumatic pressure supplies before
entering the workspace of the manipulator.
Also read the safety sections:
•
Pneumatic or hydraulic related hazards on page 32
•
•
Maintenance and repair on page 34
CAUTION
Always read the specific instructions for Clean Room robots before doing any
repair work, see
Cut the paint or surface on the robot before replacing parts on
.
Continues on next page
Product manual - IRB 360
119
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
3 Maintenance
3.4.1 Changing the battery in the measuring system
Summary of Contents for IRB 360
Page 1: ...ROBOTICS Product manual IRB 360 ...
Page 8: ...This page is intentionally left blank ...
Page 266: ...This page is intentionally left blank ...
Page 268: ...This page is intentionally left blank ...
Page 271: ......