Required equipment and references
Note
Required equipment
.
Standard tools
References
Replacement of telescopic shaft on page 182
Spare parts, telescopic shaft
.
Interval 500 h
Note
Action
Described in section
of telescopic shaft on page 182
Check and retighten the set screws in the universal
joints.
1
Interval 4000 h
Note
Action
Spare parts, telescopic shaft
Change the telescopic shaft and the universal joint.
1
After a collision and/or if arms have fallen off
Note
Action
CAUTION
Be careful when pulling out the
telescope
to full length.
Remove any remaining parts of the bar system from
the
movable plate
.
1
How to replace the universal joint,
see section:
•
Replacement of universal
joint on page 185
Check for damages on the
universal joint
.
2
How to replace the universal joint,
see section:
•
Replacement of universal
joint on page 185
Move the
movable plate
in different directions in
order to check if there are any indications of re-
duced moving ability of the
universal joint
.
3
Product manual - IRB 360
95
3HAC030005-001 Revision: Z
© Copyright 2008-2021 ABB. All rights reserved.
3 Maintenance
3.3.1 Telescopic shaft, axis 4, standard
Continued