Note
Action
xx2100002740
Loosen the 4 nuts and slide the SMB unit of the
bracket.
7
Refitting the SMB unit
Use these procedures to refit the SMB unit.
Refitting the SMB unit
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
When handling the computer outside of the con-
troller, use the wrist strap button located on the
side of the computer.
1
Tightening torque:
Fit the new SMB unit on the bracket and tighten
4 nuts.
2
3 Nm
xx2100002813
Continues on next page
114
Product manual - IRB 365
3HAC079185-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the SMB unit