4 Repair
4.2.1. Performing a leak-down test
3HAC022032-001 Revision: E
112
© Copyri
ght
200
4-2008 ABB.
All rights reserved.
4.2 General procedures
4.2.1. Performing a leak-down test
General
After refitting any motor and any gearbox, the integrity of all seals enclosing the gearbox oil
must be tested. This is done in a leak-down test.
Required equipment
Procedure
Equipment, etc.
Art. no.
Note
Leakdown tester
3HAC 0207-1
Leak detection spray
-
Action
Note
1. Finish the refitting procedure of the motor or gear in
question.
2. Remove the topmost oil plug on the gear in question,
and replace it with the leakdown tester.
Adapters may be required, which are included in the
leakdown tester kit.
Art. no. is specified above!
3. Apply compressed air, and raise the pressure with the
knob until the correct value is shown on the
manometer.
Recommended value:
0.2 - 0.25 bar (20 - 25 kPa)
4. Disconnect the compressed air supply.
5. Wait for approx. 8-10 minutes. No pressure loss must
be detected.
If the compressed air is signifi-
cantly colder or warmer than the
gearbox to be tested, a slight
pressure increase or decrease
respectively may occur. This is
quite normal.
6. Was any pressure drop evident?
Localize the leak as detailed below.
Remove the leakdown tester, and refit the oil plug.
The test is complete.
7. Spray suspected leak areas with leak detection spray.
Bubbles indicate a leak.
8. When the leak has been localized: take the necessary
measures to correct the leak.
Summary of Contents for IRB 4400 - 45
Page 2: ......
Page 8: ...Table of Contents 6 3HAC022032 001 Revision E Copyright 2004 2008 ABB All rights reserved ...
Page 296: ......
Page 297: ... Copyright 2004 2006 ABB All rights reserved Foldout 1 ...
Page 298: ... Copyright 2004 2006 ABB All rights reserved Foldout 2 ...
Page 299: ... Copyright 2004 2006 ABB All rights reserved Foldout 3 1 ...
Page 301: ... Copyright 2004 2006 ABB All rights reserved Foldout 4 ...
Page 302: ... Copyright 2004 2006 ABB All rights reserved Foldout 5 ...
Page 303: ... Copyright 2004 2006 ABB All rights reserved Foldout 6 1 ...
Page 304: ... Copyright 2004 2006 ABB All rights reserved Foldout 6 2 ...
Page 305: ... Copyright 2004 2006 ABB All rights reserved Foldout 6 3 ...
Page 307: ... Copyright 2004 2006 ABB All rights reserved Foldout 8 ...
Page 313: ... Copyright 2004 2006 ABB All rights reserved Motor Axis 1 3 Sheet 103 ...
Page 314: ... Copyright 2004 2006 ABB All rights reserved Feed Back Axis 1 3 Sheet 104 ...
Page 315: ... Copyright 2004 2006 ABB All rights reserved Motor Axis 4 6 Sheet 105 ...
Page 316: ... Copyright 2004 2006 ABB All rights reserved Feed Back Axis 4 6 Sheet 106 ...
Page 317: ... Copyright 2004 2006 ABB All rights reserved Customer Connection Sheet 107 ...
Page 318: ... Copyright 2004 2006 ABB All rights reserved Pos Indicator Axis 1 Option Sheet 108 ...
Page 321: ......