Info/Illustration
Action
Feed the cabling up through the middle of axis 1 and
remove the complete cabling.
Tip!
Gather the loose cabling and connectors into a
package with tape in order to protect the connectors and
make the cabling easier to handle.
11
Refitting, cabling axes 1-3
The procedure below details how to refit the cable harness to axes 1-3.
Info/Illustration
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off for Foundry
Prime robots!)
to the robot, before entering the robot working area.
1
Part no. is specified in
Feed the
cable harness, axes 1-3
through the protection
plate and down through the middle of axis 1.
Tip
Gather the loose cabling and connectors into a package
with tape in order to protect the connectors and make
the cabling easier to handle.
2
Part no. is specified in
Refit the connection boxes to the motors 1-2-3. Replace
the
gaskets
if they are damaged.
3
Shown in the figure
of cable harness, view X-X on
page 145
Reconnect the
connectors
in the motors 1-2-3.
4
Shown in the figure
of cable harness, view X-X on
page 145
Refit the
cable guide
and the
protection plate
in the
middle of axis 1.
5
See chapter
Exploded views
,
in
Product manual, spare
parts - IRB 4400
.
Secure the cabling with straps, according to foldout 3.
6
Refit the cable bracket inside the base.
7
See chapter
Exploded views
,
in
Product manual, spare
parts - IRB 4400
.
Reposition the cabling inside the base according to fol-
dout 4.
8
Reconnect all connectors at the base.
9
This is detailed in section
fitting, serial measurement unit
on page 209
.
Refit the serial measurement unit.
10
Shown in the figure
of cable harness, axes 1-3 on
page 144
Refit the rear cover plate.
11
Refit the covers of the connection boxes.
12
Continues on next page
Product manual - IRB 4400
147
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.3.1 Replacement of cable harness, axes 1-3
Continued
Summary of Contents for IRB 4400/60
Page 1: ...ROBOTICS Product manual IRB 4400 ...
Page 8: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 282: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 302: ......
Page 303: ......