Removal, signal cabling upper arm
The procedure below details how to remove the signal cabling from the upper arm.
Info/Illustration
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off for
Foundry Prime robots!)
to the robot, before entering the robot working
area.
1
Shown in the figure
signal cabling, upper arm on
page 176
Remove the
wrist bracket
and the
upper arm
bracket
from the upper arm.
2
Shown in the figure
signal cabling, upper arm on
page 176
Remove the
front and rear cable holders
from
the tube shaft.
3
Disconnect the connectors at the rear of the
upper arm.
4
Refitting, signal cabling upper arm
The procedure below details how to refit the signal cabling to the upper arm.
Note/Illustration
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply (do not turn off for
Foundry Prime robots!)
to the robot, before entering the robot working
area.
1
Fit transparent protection tape to the narrow
part of the tube shaft. Remove dirt and grease
from the surface first!
2
Move axis 4 to its calibration position (0°).
3
Continues on next page
Product manual - IRB 4400
177
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.4.5 Replacement of signal cabling, upper arm (option 042)
Continued
Summary of Contents for IRB 4400/60
Page 1: ...ROBOTICS Product manual IRB 4400 ...
Page 8: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 282: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 302: ......
Page 303: ......