Action
Tap the mechanical unit in question.
2
A screen is displayed, tap
Rev. Counters
.
en0400000771
Tap
Update Revolution Counters...
.
A dialog box is displayed warning that updating the revolution counters may change
programmed manipulator positions:
•
Tap
Yes
to update the revolution counters.
•
Tap
No
to cancel updating the revolution counters.
Tapping
Yes
displays the axis selection window.
3
Select the axis to have its revolution counter updated by:
•
Ticking in the box to the left
•
Tapping
Select all
to update all axes.
Then tap
Update
.
4
A dialog box is displayed warning that the updating operation cannot be undone:
•
Tap
Update
to proceed with updating the revolution counters.
•
Tap
Cancel
to cancel updating the revolution counters.
Tapping
Update
updates the ticked revolution counters and removes the tick from the
list of axes.
5
CAUTION
If a revolution counter is incorrectly updated, it will cause incorrect manipulator posi-
tioning, which in turn may cause damage or injury!
Check the calibration position very carefully after each update. See
calibration position on page 328
.
6
3HAC033453-001 Revision: H
327
© Copyright 2009-2013 ABB. All rights reserved.
5 Calibration
5.5 Updating revolution counters
Continued
Summary of Contents for IRB 4600 - 40/2.55