Note
Action
A
B
C
xx0800000456
Use caution when pushing the
base cover
into position while at the same time check-
ing that no cables are damaged.
18
Parts:
•
A: Base
•
B: Base cover
•
C: Attachment screws (6 pcs)
Secure the
base cover
with its attachment
screws.
19
See the figure in:
•
Location of the cable harness on
page 208
Refit the
bracket
on the frame.
20
See the figure in:
•
Location of the cable harness on
page 208
Refit the
cable straps
securing the cable
harness to the frame.
21
How to refit the cable harness on the
lower arm and armhouse
is described in
section:
•
Refitting the cable harness in the
lower arm and armhouse on
page 219
Continue the refitting of the cable package
on lower arm and armhouse.
22
Refitting the cable harness in the lower arm and armhouse
Use this procedure to refit the cable harness in the
lower arm
and
armhouse
.
Tip
Before starting this procedure, first refit the cable harness in the
frame
and
base
.
See:
•
Refitting the complete cable harness on page 207
•
Refitting the complete cable harness on page 207
Continues on next page
3HAC033453-001 Revision: H
219
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the complete cable harness
Continued
Summary of Contents for IRB 4600 - 40/2.55