WARNING
If the air pressure exceeds the specified, it could result in a brake failure in the
motors and cause the robot arms to fall down, leding to personal injure or physical
damage.
Note
To secure sufficient air pressure, it is recommended to use a pressure sensor.
Pressurize the motors and serial measurement board cavity
The robots are prepared with hoses to the motors and the serial measurement
board cavity to enable pressurizing of them.
WARNING
The robot must be pressurized also when it is switch off, to avoid that the humid
environmental air is sucked into the motors when cooling down.
Note/Illustration
Action
xx1500002398
Dimension: G1/8, d=6mm
Connect a compressed air hose to air con-
nector on robot base, see illustration.
1
Do this when the controller cables are
connected.
Protect the screws on the Harting connectors
on the robot base from corrosion with Mer-
casol.
2
See
Air specification for pressurizing of
for correct pressure.
Pressurize the robot.
3
See
Inspection of air hoses (Foundry
.
Inspect the air system.
4
Protecting from high pressure water
WARNING
No part of the robot are allowed to be exposed to direct high pressure jet of water.
The sealings between the moving parts on the wrist must not be exposed to
direct or rebounding high-pressure jet of water.
Continues on next page
102
Product manual - IRB 4600 Foundry Prime
3HAC040585-001 Revision: M
© Copyright 2013-2018 ABB. All rights reserved.
2 Installation and commissioning
2.10.1 Installation of IRB 4600 Foundry Prime in a water jet application
Continued
Summary of Contents for IRB 4600 Foundry Prime
Page 1: ...ROBOTICS Product manual IRB 4600 Foundry Prime ...
Page 106: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 400: ...This page is intentionally left blank ...
Page 406: ......
Page 407: ......