Refitting SMB battery
Use this procedure to refit the SMB battery.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
to the robot, before entering the robot working area.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
The unit is sensitive to ESD on page 31
2
See the figure in
Reconnect the
battery cable
to the
SMB battery
.
3
See the figure in
Put the battery unit into its recess while arranging
the SMB cables as shown in the figure.
4
See the figure in
Secure the
SMB cover
with its
attachment screws
.
5
Seal and paint the joints that have been opened.
Also repair possible damages of the special Foundry
Prime paint coat of the robot. See
surface on the robot before replacing parts on
page 201
.
6
Detailed in
Update the revolution counter.
7
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further de-
tailed in the section
First test run may cause injury
8
Product manual - IRB 4600 Foundry Prime
189
3HAC040585-001 Revision: M
© Copyright 2013-2018 ABB. All rights reserved.
3 Maintenance
3.5.8 Replacing SMB battery
Continued
Summary of Contents for IRB 4600 Foundry Prime
Page 1: ...ROBOTICS Product manual IRB 4600 Foundry Prime ...
Page 106: ...This page is intentionally left blank ...
Page 194: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 400: ...This page is intentionally left blank ...
Page 406: ......
Page 407: ......