Note
Action
xx0900000015
Refit the
earth cables
.
4
Parts:
•
A: Earth
•
B: Distance screws
Connect the contacts on the SMB unit:
•
R1.SMB1-2
•
R1.SMB3-6
•
R2.SMB
5
How to refit the SMB unit is described in
section:
•
Refitting the SMB unit on page 249
Refit the SMB unit.
6
A
xx0900000035
Refit the cables with the
screen connec-
tions
.
7
Parts:
•
A: Screen connections (4 pcs)
xx0900000013
Tip
When refitting connectors on the
bracket
,
put it at a 90° angle.
8
Parts:
•
A: Bracket
•
B: Base
Continues on next page
226
Product manual - IRB 4600 Foundry Prime
3HAC040585-001 Revision: M
© Copyright 2013-2018 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the complete cable harness
Continued