Note
Action
xx2100002134
Remove the electronic box screws.
3
xx2100002135
Remove the electronic box, including all internal
equipment.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
4
Disconnecting the SMB and brake release units
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
1
Disconnect all connectors from the SMB board.
2
Disconnect the connectors R2.BU1 and R2.BU2 from
the brake release board.
3
Removing the cable harness from the base
Note
Action
xx2100001111
Pull out the robot cable harness through
the protection tube.
1
Place the cable harness safely on the
frame.
2
Continues on next page