Note
Action
Flange sealant: 3HAC041807-007
(Loctite 5800)
xx2100000520
Apply a continuous bead of flange sealant, 1-2
mm wide, inside of the groove on the motor con-
tact surface.
Note
The purpose of the groove is to catch excess
sealant. No o-ring is used.
3
xx2100000596
Remove the cover, if fitted to the new spare part
motor.
4
Tightening torque, transparent
plug: 20 Nm
Protection type Foundry Plus
Valid for axis-1, axis-2, axis-3 and axis-4.
5
Tightening torque, protection filter:
20 Nm
xx1600000576
If the motor is a new spare part, the evacuation
hole protection filter must be replaced with a
transparent plug/sight glass (enclosed with the
spare part delivery). Remove the protection filter
and install the transparent plug/sight glass.
xx1800000102
Transparent plug
(Foundry Plus).
xx1800000101
Protection filter (Stand-
ard).
Continues on next page
392
Product manual - IRB 5720
3HAC079195-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.8.5 Replacing the axis-5 motor
Continued
Summary of Contents for IRB 5710
Page 1: ...ROBOTICS Product manual IRB 5720 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 186: ...This page is intentionally left blank ...
Page 580: ...This page is intentionally left blank ...
Page 604: ...This page is intentionally left blank ...
Page 609: ......