Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
Shown in
lower end (axes 1-3) on page 150
Remove the
rear cover plate
from the robot by
removing its attachment screws.
3
Shown in
lower end (axes 1-3) on page 150
Disconnect the
earth cable
.
4
See the figure
ness - lower end (axes 1-3) on
page 150
.
Disconnect the connectors
R1.MP
and
R1.SMB
.
5
xx0600002698
•
A: Cable guide ax 2
Unscrew the screws of the
cable guide axis 2
inside the lower arm and loosen the cable
guide.
6
Shown in
lower end (axes 1-3) on page 150
Unscrew the screws in the
metal clamps
hold-
ing the cable harness in the frame and lower
arm.
7
Unscrew the screws of the motor covers for
axes 1, 2 and 3 and lift away the covers. This
is done in order to reach the motor connectors.
8
Continues on next page
Product manual - IRB 660
153
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
4 Repair
4.3.1 Replacing cable harness, lower end (axes 1-3)
Continued