Removing motors axes 2 and 3
Use this procedure to remove motors axes 2 and 3.
The procedure is the same for both motors.
Note
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning the
repair procedure.
1
xx1000001101
Run the robot to a position close enough to its
calibration position, to allow the lock screw to
be inserted into the
hole for lock screw
.
2
See figure above.
Lock the
lower arm
by inserting the
lock screw
into the hole of the frame.
3
This is done in order to secure axis 2 from col-
lapsing when the axis 2 motor is being removed.
CAUTION
Tighten by hand!
Run axis 3 to the end position so that it rests
against the mechanical stop. Release the brake
of axis 3 in order to set the weight of axis 3
against the mechanical stop.
4
This is done in order to secure axis 3 from col-
lapsing when the axis 3 motor is being removed.
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
5
See section
•
Changing oil, gearbox axes 2
and 3 on page 126
.
Drain the oil from
gearbox
.
6
Continues on next page
260
Product manual - IRB 660
3HAC025755-001 Revision: W
© Copyright 2006-2020 ABB. All rights reserved.
4 Repair
4.6.2 Replacing motors, axes 2 and 3
Continued
Summary of Contents for IRB 660
Page 1: ...ROBOTICS Product manual IRB 660 ...
Page 8: ...This page is intentionally left blank ...
Page 332: ...This page is intentionally left blank ...
Page 352: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 360: ......
Page 361: ......