3 Maintenance
3.4.8. Replacement of SMB battery
3HAC023082-001 Revision: E
200
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
3.4.8. Replacement of SMB battery
Location of SMB battery
The SMB battery (SMB = serial measurement board) is located on the left hand side of the
frame as shown in the figure below.
Note that the robot is shown with the SMB cover already removed!
xx0200000238
Required equipment
Removal, battery
The procedure below details how to remove the SMB battery.
A
SMB battery cover
B
SMB battery pack
C
Battery cable
Equipment, etc.
Spare part no.
Note
Battery pack
3HAC 16831-1
Battery includes protection circuits. Replace it
only with given spare part no. or an ABB
approved eqvivalent.
Standard toolkit
-
The contents are defined in section
in part 2 of the Product
manual.
Circuit Diagram
See chapter
Circuit diagram
in the
Product
manual, reference information
.
Action
Note
1. Move the robot to its calibration position.
This is done in order to facilitate the
updating of the revolution counter.
Continues on next page