3 Maintenance
3.4.8. Replacement of SMB battery
201
3HAC023082-001 Revision: E
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
Refitting, battery
The procedure below details how to refit the SMB battery.
2.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the air
pressure to motors and SMB.
3.
esd
WARNING!
The unit is sensitive to ESD, before handling the
unit please observe the safety information in
section
WARNING - The unit is sensitive to ESD!
4. Remove the
SMB battery cover
by unscrewing its
attachment screws.
Shown in the figure
.
5. Pull out the battery and disconnect the
battery
cable
.
Shown in the figure
.
6. Remove the
SMB battery.
Battery includes protection circuits. Replace it
only with the specified spare part or with an ABB
approved eqvivalent.
Shown in the figure
.
Action
Note
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off the
air pressure to motors and SMB.
2.
esd
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section
WARNING - The unit is sensitive to
Continued
Continues on next page