4 Repair
4.6.2. Replacement of motor axis 2
349
3HAC023082-001 Revision: E
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
8.
DANGER!
Secure the weight of the lower arm properly
before releasing the brakes of motor, axis 2!
When releasing the holding brakes of the motor,
the lower arm will be movable and may fall down!
9. Continue to remove the motor unit, according to
step 9 to 17 in
.
10. Fill the four screw recesses on the new motor with
Sikaflex. (After hardening, Sikaflex can be formed
with a knife)
xx0600002875
•
A: motor unit
•
B: Sikaflex in screw
recesses
11. Continue to refitt the new motor according to,
.
12. Perform a leak test according to
hoses (Foundry Prime) on page 176
Action
Note/Illustration
Continued