4 Repair
4.6.5. Replacement of motor, axis 5, IRB 6600 and IRB 6650
3HAC023082-001 Revision: E
368
©
Co
py
rig
h
t 200
4-
200
8 ABB. All righ
ts reser
v
ed.
8. In order to release the brake, connect the 24
VDC power supply.
Connect to either:
- connector R4.MP5 (in the motor):
•
+: pin 2
•
-: pin 5
- connector R3.MP5 (on the separate
cable, if not removed):
•
+: pin C
•
- : pin D
9. Fit the two
guide pins
in two of the motor
attachment holes.
Art. no. is specified in
!
10. Fit the motor, with guidance from the pins,
making sure the motor pinion is properly mated
to the gear of axis 5.
Make sure the motor pinion does not
get damaged!
11. Secure the motor with four attachment screws
and plain washers.
4 pcs: M8 x 25; tightening torque: 24
Nm.
12. Disconnect the brake release voltage.
13. Refit theseparate cable of the axis 5 motor and
reconnect all connectors beneath the motor
cover.
14. Refit the cable gland cover at the cable exit
with its two attachment screws.
15. Refit the cover on top of the motor with its four
attachment screws.
Make sure the cover is tightly sealed!
16. Perform a leak-down test.
Detailed in section
.
17. Refit the wrist unit.
Detailed in section
18. Refill the gear with oil.
Detailed in section
19. Recalibrate the robot.
Calibration is detailed in a separate
calibration manual, enclosed with the
calibration tools.
General calibration information is
included in section
.
20.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in section
run may cause injury or damage! on page 38
.
Action
Note
Continued
Continues on next page